Ignition "OFF"
Disconnect ambient temperature sensor.
Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature.
1. Sensor Ground | 2. Ambient Sensor Signal |
Ambient temperature [℃(℉)] | Resistance between terminals 1and 2 (㏀) |
-30(-22) | 480.41 |
-20(-4) | 271.21 |
-10(14) | 158.18 |
0 (32) | 95.10 |
10 (50) | 58.80 |
20 (68) | 37.32 |
30(86) | 23.76 |
40(104) | 16.13 |
50(122) | 10.95 |
If the measured resistance is not specification, substitute with a known-good ambient temperature sensor and check for proper operation.
If the problem is corrected, replace the ambient temperature sensor.