Diagnostic Procedure
1.

Turn on A/CON and electric devices (head lamp, defogger…etc).

2.

Monitor current data at 2,000 rpm (idle)

■ Specification : 12.0 ~14.8 V

caution

This current data is nothing but an example at certain condition. Thus, the real current data could be different from this example.

3.

Is battery voltage normal?

▶ Go to "Coolant inspection" procedure.

▶ Go to "Cooling fan inspection" procedure.

▶ Go to "Spark plug inspection" procedure.

▶ Check electrical accessory installation.

▶ Check tension of the alternator belt.

▶ Check battery terminal and B+ terminal of the alternator (tightening condition and corrosion).

▶ Replace battery and alternator.