Check visually cooling fan whether it is operated always or not when A/conditioner switch is turned off.
Is cooling fan operated always when A/conditioner switch is turned off?
This current data is nothing but an example at certain condition. Thus, the real current data could be different from this example.
![]() | ▶ Go to "ECM inspection" procedure as below. |
![]() | ▶ Go to "Coolant inspection" procedure. ▶ Go to "Spark plug inspection" procedure. ▶ Go to "Alternator inspection" procedure. |
Connect probe of the LED circuit tester to "high speed control" terminal or "low speed control" terminal of the ECM harness connector.
☞ Connect tongs of the LED circuit tester to battery (+) terminal.
Perform fan-high (fan-low) actuation test using a GDS.
Check for LED lamp on the circuit tester while actuation testing.
■ Specification : LED lamp is lit while actuation testing.
Is LED lamp circuit tester lit normally?
![]() | ▶ Go to "Coolant inspection" procedure. ▶ Go to "Spark plug inspection" procedure. ▶ Go to "Alternator inspection" procedure. |
![]() | ▶ Repair control circuit between cooling fan harness connector and ECM harness connector as necessary. ▶ Check for ECM. |