Componet Location
General Description

The Evaporator sensor located on the HVAC unit and detects the evaporator core temperature. It is a negative type thermistor whose resistance is inversely proportional to temperature. The Evaporator sensor converts the measured temperature into a voltage value and delivers it to A/C ECU. When core temperature is blow threshold value, A/C ECU interrupts compressor relay power, in order to prevent evaporator freezing by excessive cooling.

DTC Description

DTC B1242 sets if Evaporator sensor signal is at or over 4.9V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

1.

Open in signal circuit

2.

Short to battery in signal circuit

3.

Faulty Evaporator sensor

4.

Faulty Air conditioner control Unit

Enable Conditions

Ignition ON

Threshold value

Evaporator sensor signal is at or over 4.9V for 0.3 seconds.

Failsafe

Control with the value of -2℃(28.4℉)

Specification

※ Resistance value of evaporator sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-10/-14

43.3

20/68

12.1

0/32

27.6

30/86

8.3

10/50

18

40/104

5.8

Diagnostic Circuit Diagram