Componet Location
General Description

The air mix actuator(Temperature Actuator) is located at heater unit. It contains temp motor that changes temp door position and potentiometer that monitors position of temp door.The air mix actuator regulates the temperature by the procedure as follows. Signal from control unit adjusts position of temp door by operating temp motor and then temperature will be regulated by the hot/cold air ratio decided by position of temp door. In operation, potentiometer delivers temp door position transformed into voltage value to A/C ECU.

DTC Description

DTC B1245 sets if the Driver Air mix actuator(Temperature actuator) Sensor signal is at or below 0.1V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

1.

Poor Conection in harness

2.

Open in signal(Feedback signal), power and ground circuit

3.

Faulty Driver air mix actuator

4.

Faulty Air condition Contorl Module

Enable Conditions

Ignition ON

Threshold value

Driver air mix actuator Sensor signal is at or below 0.1V for 0.3 seconds.

Failsafe

Setting temperature : 63℉-76.1℉, fix at max. cooling position

Setting temperature : 77℉-89.6℉, fix at max. heating position

Specification

※ Voltage value of Air Mix potentiometer as a function of temp door position.

Door position

Voltage

Max. cool

0.3±0.15V

Max. warm

4.7±0.15V