Monitor Scantool data
■ Actuation Test
1.

Connect scantool with diagnostic connector.

2.

Warm up the engine to normal temperature after engine start.

3.

Select and monitor "Auto defoger mode direction potentioner" parameter on current data.

4.

Perform Actuation Test for "Auto Defoger Mode Door -0%(close)/50%/100%(open)" in order.

5.

Check that the value of auto defoger mode actuator is changed with performing actuation test.

Specification : 0%(close) : About 90%, 50% : About 55%, 100%(open) : About 20%.

6.

Does the value of auto defoger mode actuator follow the specification ?

▶ This may be a intermittent problem caused by poor contact of component or the Control Unit.

▶ Thoroughly check for looseness, poor connection, bent, corrison, contamination, deformation or damage of connector.

▶ Monitoring with a DVOM on min/max or VMI while wiggling connectors may help find the problem. Any change in voltage indicate a possible problem.

▶ Repair or replace as necessary and then, go to "Verification of Vehicle Repair" procedure.

▶ Go to " Inspection/Repair" procedure.

Яндекс.Метрика