Monitor Scantool Data
1.

Connect scantool to Data Link Connector (DLC).

2.

Engine "ON".

3.

Select the " PAS Active" parameter among Current Data.

4.

Check the data chagnes by pressing ON/OFF switch of PAS Active.

Fig.1) PAS Active

5.

Is the measured value within specifications?

▶ Fault is intermittent caused by poor connection in PAS Switch and SPAS ECU's connector or was repaired and SPAS ECU memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.

▶ Go to "Termminal Connector Inspection" procedure.