Check for continuity and measure the resistance between No.4 and No.6 terminals.
No. | Description | No. | Description |
1 | NTC | 4 | GND |
2 | - | 5 | GND |
3 | NTC | 6 | VCC |
Standard value (Fabric / Leather)
Cushion : 3.89 Ω ± 10%
Back: 3.11 Ω ± 10% / 4.13 Ω ± 10%
Set : 7.0 Ω ± 10% / 8.9 Ω ± 10%
Operate the seat heater after connecting the connector, and then check the thermostat by measuring the temperature of seat surface.
Standard value (Fabric / Leather)
Cushion :
1 Step : 40 ± 2°C(104 ± 3.6°F)
2 Step : 42 ± 2°C(107.6 ± 3.6°F)
Back :
1 Step : 46 ± 2°C(114.8 ± 3.6°F)
2 Step : 52 ± 2°C(125.6 ± 3.6°F)