Inspection
1.

Ignition "OFF"

2.

Disconnect evaporator temperature sensor.

3.

Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.

Specification

Evaporator core

temperature[°C(℉)]

Resistance[KΩ]

-10 / (14)

43.35

0 / (32)

27.62

10 / (50)

18.07

20 / (68)

12.11

30 / (86)

8.30

40 / (104)

5.81

Replacement
1.

Disconnect the negative (-) battery terminal.

2.

Loosen the mounting screw and then remove the crash pad lower cover (A).

3.

Remove the evaporator temperature sensor (A), by pulling it after rotating 90° in a counterclockwise direction.

4.

Installation is the reverse order of removal.