Installation
1.

Installation is reverse of removal.

note

When installing the high pressure fuel pipe, apply the specified tightening torques with the special service tool (Refer to below table).

Item

Dimension

SST No.

Flange Nut

(Injector Side)

14 mm (0.551 in)

09314-27110

Flange Nut

(HP Pump Side)

Flange Nut

(Common

Rail Side)

17 mm (0.669 in)

09314-27120

· Common rail installation bolts:

14.7 ~ 21.6 N.m (1.5 ~ 2.2 kgf.m, 10.9 ~ 15.9 lb-ft)

· High pressure fuel pipe installation nut:

24.5 ~ 28.4 N.m (2.5 ~ 2.9 kgf.m, 18.1 ~ 20.1 lb-ft)