Component Location
General Description

The air mix actuator(Temperature Actuator) is located at heater unit. It contains a motor that changes temp door position and a potentiometer that monitors the position of the temp door. The Air Conditioning Control Unit controls the temperature by commanding the temp door motor to move.

DTC Description

The Airconditioner Control Module sets DTC B1204 if the Feed Back signal of Passenger Air mix actuator(Temperature actuator) has been detected open or below 0.1V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

1.

Poor connection of connected part

2.

Open in signal circuit (Feedback circuit), Power circuit or Ground Circuit

3.

Faulty passenger air mix actuator

4.

Faulty A/C control unit

Enable Conditions

IG KEY ON

Threshold value

Feedback signal has been detected open or below 0.1V for 0.3 seconds

Failsafe

setting temperature : 16℃(62.6℉)-24℃(76.1℉) fix at max. cooling position

setting temperature : 25℃(77℉)-31℃(89.6℉) fix at max. heating position

Specification

※ Voltage value of Air Mix potentiometer as a function of temp door position.

Door position

Voltage

Max. cool

0.3±0.15V

Max. warm

4.7±0.15V

Diagnostic Circuit Diagram
Яндекс.Метрика