The air mix actuator(Temperature Actuator) is located at heater unit. It contains a motor that changes temp door position and a potentiometer that monitors the position of the temp door. The Air Conditioning Control Unit controls the temperature by commanding the temp door motor to move.
The Airconditioner Control Module sets DTC B1205 if the Feed Back signal of Passenger Air mix actuator(Temperature actuator) has been detected over 4.9V for 0.3 seconds.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Voltage check | 1. Short to battery in signal(Feedback) circuit. 2. Faulty passenger air mix actuator. 3. Faulty A/C control unit. |
Enable Conditions |
•
IG KEY ON | |
Threshold value |
•
Feedback ciruit has been detected over 4.9V for 0.3 seconds. | |
Failsafe |
•
setting temperature :16℃(62.6℉)-24℃(76.1℉) fix at max. cooling position
•
setting temperature : 25℃(77℉)-31℃(89.6℉) fix at max. heating position |
※ Voltage value of Air Mix potentiometer as a function of temp door position.
Door position | Voltage |
Max. cool | 0.3±0.15V |
Max. warm | 4.7±0.15V |