Componet Location
General Description

The air mix actuator(Temperature Actuator) is located at heater unit. It contains temp motor that changes temp door position and potentiometer that monitors position of temp door.The air mix actuator regulates the temperature by the procedure as follows. Signal from control unit adjusts position of temp door by operating temp motor and then temperature will be regulated by the hot/cold air ratio decided by position of temp door. In operation, potentiometer delivers temp door position transformed into voltage value to A/C ECU.

DTC Description

The Air conditioner Control Module sets DTC B2406 if Driver air mix actuator has not been moved to the mode,where air condition control module controls, within 40 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

1.

Poor contact in harness

2.

Open or short in motor power circuit

3.

Faulty Driver air mix actuator

4.

Faulty air conditioner control module

Enable Conditions

IG KEY ON

Threshold value

No movement to controlled mode position for 40 seconds

Failsafe

Fixed as current position

Specification

※ Voltage value of Air Mix potentiometer as a function of temp door position.

Door position

Voltage

Max. cool

0.3±0.15V

Max. warm

4.7±0.15V

Diagnostic Circuit Diagram
Яндекс.Метрика