Componet Location
General Description

The Evaporator sensor located on the HVAC unit and detects the evaporator core temperature. It is a negative type thermistor whose resistance is inversely proportional to temperature. The Evaporator sensor converts the measured temperature into a voltage value and delivers it to A/C ECU. When core temperature is blow threshold value, A/C ECU interrupts compressor relay power, in order to prevent evaporator freezing by excessive cooling.

DTC Description

DTC B1241 sets if the Evaporator Sensor signal is at or below 0.1V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage check

1.

Short circuit in harness

2.

Faulty Evaporator sensor

3.

Faulty A/C Control Unit

Enable Conditions

Ignition ON

Threshold value

Evaporator Sensor signal is at or below 0.1V for 0.3 seconds.

Failsafe

Control with the value of -2℃(28.4℉)

Specification

※ Resistance value of evaporator sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-10/-14

43.3

20/68

12.1

0/32

27.6

30/86

8.3

10/50

18

40/104

5.8

Diagnostic Circuit Diagram