Component Location
General Description

The Fuel Level Sensor(FLS) measures the fuel level in fuel tank and its information is used to supply the PCM with information regarding the monitoring condition of the EVAP canister purge system for leak detection. If the fuel level sensor is monitored for high or low stuck or difference between voltage of fuel level sensor and voltage deviation of fuel level sensor is exceeds limited value while driving, this is interpreted by the PCM as a fault.

DTC Description

PCM sets DTC P0462 if the PCM detects that the control line is short to ground.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Electrical check (Short to Ground)

1.

Short to ground in signal circuit

2.

Poor connection or damaged harness

3.

Faulty Fuel Level Sender "A"

Enable Conditions

Delay time when failure present : 200 Seconds

11< Battery voltage < 16

Threshold Value

Fuel Level Signal < 0.04V

Diagnostic Time

220 Seconds

Mil On Condition

2 Drive Cycles

Specification

FLOAT Position

S/F

G/F

7/8

6/8

5/8

1/2

3/8

2/8

-

1/8

W/G

G/E

S/E

Sender Resist(Ω)

4±1

11±1

32±1

53±1

74±1

-

-

74±2

-

92.4±2

105±2

113.4±2

130.4±2

(S/F:Sensing Full, G/F : Guage Full, W'G:Warning lamp ON, G/E : GUAGE Empty, S/E : Sensing Empty)

Diagnostic Circuit Diagram
Яндекс.Метрика