Installation
note

Install the component with the specified torques.

Note that internal damage may occur when the component is dropped. If the component has been dropped, inspect before installing.

caution

Be careful not to enter foreign matter into the sensor and cylinder head.

Apply dry solvents, spindle oil, gasoline to the sensor O-ring.

Tighten the bolt (B) after inserting the lug of the magnet wheel (A) into groove of the shaft completely.

note

Do not re-use the O-ring.

Be careful not to contact foreign matter to the surface of the magnet when installing the magnet wheel.

Replace the sensor and the magnet together at the same time when replacing those.

Be careful not to install O-ring incorrectly.

1.

Install the CVVL position sensor in the reverse of removal.

Vacuum pipe assembly installation bolt: 9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

CVVL position sensor installation bolt: 9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

Magnet wheel installation bolt: 9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)