DTC Description

P0135 is an evaluate O2 Sensor heater performance pending DTC, root causes will be confirmed by P0030, P0606, P2243, P2251.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Evaluate Upstream O2 Sensor Heater performance

1.

Poor Connector Connection

2.

Defected related fuse

3.

Open/Short in Power Circuit

4.

Open/Short in Heater Control Circuit

5.

Defected Upstream O2 Sensor

Enable

Condition

Case 1

Engine speed during engine start higher than 640 RPM to 960 RPM depending on start ECT

Heater Pulse Width Modulation(PWM) higher than 1.56%

Upstream O2 sensor pre-heating phase finished

Upstream O2 sensor operative readiness detected;

[Upstream O2 sensor tip Temp. higher than 1,184℉(640℃) or 18 sec. elasped after dew-point exceeded]

18 sec. after dew-point exceeded

Battery voltage higher than 11 V and lower than 16 V

No relevant DTC present

Case 2

Battery voltage higher than 11 V and lower than 16 V

Threshold

Value

Case 1

Upstream O2 sensor tip Temp. lower than 1,391℉(755℃)

Upstream O2 sensor tip Temp. higher than 1,652℉(900℃)

Case 2

Error bit information from HW circuit

Diagnostic Time

O2 sensor tip Temp. less than 1,184℉(660℃) : 1 sec.

O2 sensor tip Temp. higher than 1,184℉(660℃) and less than 1,391℉(755℃) : 10 sec.

O2 sensor tip Temp. higher than 1,652℉(900℃) : 10 sec.

MIL ON Condition

2 Driving Cycle

Яндекс.Метрика