DTC Description

The PCM monitors the exhaust camshaft sensor signal transition position which must change only once per crankshaft revolution. If no camshaft signal is detected while crankshaft signal is detected, the PCM sets DTC P0365.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC

Strategy

Case 1

Missing Signal Monitoring

1.

Poor Connector Connection

2.

Open or Short in Exhaust Camshaft Sensor Circuit

3.

Misadjust crankshaft and camshaft pulley position

4.

Defected Exhaust CMPS

Case 2

Out of Range Monitoring

Enable Condition

First CRK Long teeth passed

Threshold

Value

Case 1

Number of revolutions without Camshaft edge more than 8 rev. after synchronization, 6 rev. before synchronization

Case 2

More than 6 rev. with camshaft edge out of designed reference position window(18˚ CRK angle difference compared to reference position)

Diagnostic

Time

Case 1

8 Revs.

Case 2

6 Revs.

MIL ON Condition

2 Driving Cycle