This code is set when right head lamp high circuit is shorted to ground while right head lamp high operating.
Item | Detecting Condition | Possible Cause |
DTC Strategy |
•
Load Mornitoring | 1. Poor connection 2. Short to ground in right head lamp high circuit 3. Faulty right head lamp high 4. Faulty SJB |
Enable Conditions |
•
IG KEY ON. | |
Threshold Value |
•
Right head lamp high Circuit Short to Ground. | |
Diagnostic Time |
•
It immediately sets DTC after fault detects. | |
DTC Erasing Time |
•
-Present Failure : IGN SW OFF or H/LP HI SW OFF after fault has been fixed.
•
-Memorized Failure : DTC can be erased immediately with GDS. |