Install in the reverse order of removal.
When installing the high pressure fuel pipe, apply the specified tightening torques with the special service tool (Refer to below table).
Item | Dimension | SST No. |
Flange Nut (Injector Side) | 14 mm (0.551 in) | 09314-27110 |
Flange Nut (HP Pump Side) | ||
Flange Nut (Common Rail Side) | 17 mm (0.669 in) | 09314-27120 |
· Common rail installation bolts:
14.7 ~ 21.6 N.m (1.5 ~ 2.2 kgf.m, 10.9 ~ 15.9 lb-ft)
· High pressure fuel pipe installation nut:
24.5 ~ 28.4 N.m (2.5 ~ 2.9 kgf.m, 18.1 ~ 20.1 lb-ft)