Inspection
1.

Turn the ignition switch OFF.

2.

Disconnect the RCV control solenoid valve connector.

3.

Measure resistance between the valve terminals 1 and 2.

4.

Check that the resistance is within the specification.

Specification: Refer to “Specification”

Removal
1.

Turn the ignition switch OFF and disconnect the battery negative (-) cable.

2.

Remove the RCV control solenoid valve after disconnect the connector (A), bolt (B) and RCV hose (C).

Installation
caution
●

Do not apply oil when hose assembled.

●

The hose should be inserted perfectly to nipple.

1.

Installation is the reverse order of removal.

RCV Control Solenoid Valve mounting bolt:

7.8 ~ 8.8 N.m (0.8 ~ 0.9 kgf.m, 5.8 ~ 6.5 lb-ft)