Inspection
First Seat Heater
1.

Check for continuity and measure the resistance between No.4 and No.6 terminals.

[Cushion]

No.

Description

No.

Description

1

NTC

4

GND

2

-

5

GND

3

NTC

6

VCC

[Back]

Standard value (Fabric / Leather)

Cushion : 3.89 Ω ± 10%

Back: 3.11 Ω ± 10% / 4.13 Ω ± 10%

Set : 7.0 Ω ± 10% / 8.9 Ω ± 10%

2.

Operate the seat heater after connecting the connector, and then check the thermostat by measuring the temperature of seat surface.

Standard value (Fabric / Leather)

Cushion :

1 Step : 40 ± 2°C(104 ± 3.6°F)

2 Step : 42 ± 2°C(107.6 ± 3.6°F)

Back :

1 Step : 46 ± 2°C(114.8 ± 3.6°F)

2 Step : 52 ± 2°C(125.6 ± 3.6°F)

Яндекс.Метрика