Inspection
Ignition Lock Switch Inspection
1.

Disconnect 2P-connector from a ignition lock switch.

2.

Disconnect the ignition lock switch. (if you can install a tester with the switch fixed, this step can be omission)

3.

Check for continuity between terminals. (refer to the table below)

note
●

If there is difference between what tested and the table above, replace the ignition lock switch with a new one.

Pedal position

Clutch switch

Ignition lock

switch

Released 

Pressed

(Continuity)

Released (Open)

Fully pressed 

Released (Open)

Pressed

(Continuity)

Standard value

Full stroke (A): 12.0 ± 0.3mm (0.4724 ± 0.0118 in.)

ON-OFF point (B): 2.0 ± 0.3mm (0.0787 ± 0.0118 in)

4.

If there is difference between what tested and the table above, replace the ignition lock switch with a new one.