Installation
note
●

Install the component with the specified torques.

●

Note that internal damage may occur when the component is dropped. If the component has been dropped, inspect before installing.

caution
●

Be careful not to enter foreign matter into the sensor and cylinder head.

●

Apply dry solvents, spindle oil, gasoline to the sensor O-ring.

●

Tighten the bolt (B) after inserting the lug of the magnet wheel (A) into groove of the shaft completely.

note
●

Do not re-use the O-ring.

●

Be careful not to contact foreign matter to the surface of the magnet when installing the magnet wheel.

●

Replace the sensor and the magnet together at the same time when replacing those.

●

Be careful not to install O-ring incorrectly.

1.

Install the CVVL position sensor in the reverse of removal.

Vacuum pipe assembly installation bolt: 9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

CVVL position sensor installation bolt: 9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

Magnet wheel installation bolt: 9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)