Terminal and Connection Inspection
1.

Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.

2.

Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.

3.

Has a problem been found?

▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure.

▶ Go to next step as below

Power Circuit Inspection
1.

IG KEY OFF.

2.

Disconnect CVVL connector.

3.

IG Key ON

4.

Measure voltage between of power terminal CVVL harness connector and chassis ground.

Specification : Approx. 5V

5.

Is the measured voltage within specification ?

▶ Go to next step as below.

▶ Repair or replace as necessary and then, go to "Verification of Vehicle Repair" procedure.

Ground Circuit Inspection
1.

Ignition "OFF"

2.

Disconnect CVVL connector

3.

Measure the resistance between power supply terminal of CVVL harness connector and chassis ground.

Specification : Infinite

4.

Is resistance within the specification?

▶ Go to next step as below

▶ Repair or replace as necessary and then, go to "Verification of Vehicle Repair" procedure.