Component Location
■ BINARY, LINEAR

1. Oxygen Sensor (B1/S1)

General Description
■ Binary

The normal operating temperature of the HO2S(Heated Oxygen Sensor) ranges from 350 to 850℃(662 to 1562℉). The HO2S heater greatly decreases the amount of time required for fuel control to become active. The PCM provides a pulse width modulated control circuit to adjust current through the heater. When the HO2S is cold, the value of the resistance is low and the current in the circuit is high. On the contrary, if the temperature in the resistor of the sensor rises, the current drops gradually.

■ Linear

The normal operating temperature of the HO2S(Heated Oxygen Sensor) ranges from 350 to 850℃(662 to 1562℉). The HO2S heater greatly decreases the amount of time required for fuel control to become active. The PCM provides a pulse width modulated control circuit to adjust current through the heater. When the HO2S is cold, the value of the resistance is low and the current in the circuit is high. On the contrary, if the temperature in the resistor of the sensor rises, the current drops gradually.

DTC Description
■ Binary

The PCM monitors the HO2S(B1/S1) transition frequency for predetermined time. During the monitoring period, the PCM calculates transition times that the front HO2S switches from rich to lean and from lean to rich. With this information, an average frequency for all switches can be determined. The PCM sets DTC P0133 when the average frequency is too slow.

■ LINEAR

The PCM monitors front oxygen sensor amplitude level and compares it to predetermined minimum amplitude value which could increase emission or disturb lambda control by the effect of aging on the oxygen sensor. The PCM sets DTC P0133 when the amplitude of oxygen sensor is equal to or less than minimum amplitude threshold.

DTC Detecting Condition
Binary

Item

Detecting Condition

Possible Cause

DTC Strategy

Check Lambda control regulation frequency

1.

Leak in intake or exhaust system

2.

Poor connection or damaged harness

3.

HO2S contamination

Enable Conditions

Coolant temperature >73℃(163℉)

550℃(1022℉)< Catalyst temperature model <850℃(1562℉)

Vehicle speed >3mph

1300< Engine speed(rpm) <3200rpm

0.3g/rev.< MAF <0.8g/rev.

Canister load <0.5

Lambda control active

Stable driving condition

No opening/closing of canister purge valve

70kPa(700hPa)< Ambient pressure

No relevant failure

11V< Battery voltage <16V

Threshold Value

Average Ratio between measured and maximum allowed frequency >1

Diagnostic Time

50 lambda controller cycles

Mil On Condition

2 Driving Cycles

Linear

Item

Detecting Condition

Possible Cause

DTC Strategy

Check HO2S Signal Amplitude

1.

Leak in intake or exhaust system.

2.

Poor connection or damaged harness

3.

HO2S contamination

Enable Conditions

see catalyst diagnosis(P0420) activation condition

No relevant failure

11V<Battery voltage<16V

Threshold Value

Integral ( Lambda signal amplitude measured / Lambda signal amplitude of a slow sensor ) > 1.0

Diagnostic Time

25 lambda controller cycle

Mil On Condition

2 Driving Cycles

Diagnostic Circuit Diagram

BINARY

LINEAR

Яндекс.Метрика