DTC Description

PCM sets DTC P06A5 if the PCM detects reference voltage of Sensors are higher than threshold value.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Electrical Monitoring

1.

Poor Connector Connection

2.

Short to Battery in Power Circuit

3.

Defected A/C Pressure Sensor

4.

Defected Fuel Tank Pressure Sensor

5.

Defected Fuel Rail Pressure Sensor

Enable Conditions

Ignition Key "ON"

Threshold Value

Power Supply Voltage for Sensors higher than 5.5V

Diagnostic Time

Continuous

MIL On Condition

1 Driving Cycle