DTC Description

If short short to ground in IAT signal circuit is detected, PCM sets DTC P0112.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage Monitoring

1.

Poor Connector Connection

2.

Short to Ground in IAT Signal Circuit

3.

Defected IAT Sensor

Enable Conditions

•

Battery voltage higher than 6 V and lower than 16 V

•

105 sec. after engine start

•

No relevant DTC present

Threshold Value

•

Intake air temperature signal voltage higher than 4.93V (266℉/130℃)

Diagnostic Time

•

Continuous

Mil On Condition

•

2 Driving Cycle