DTC Description

If short short to ground in IAT signal circuit is detected, PCM sets DTC P0112.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage Monitoring

1.

Poor Connector Connection

2.

Short to Ground in IAT Signal Circuit

3.

Defected IAT Sensor

Enable Conditions

Battery voltage higher than 6 V and lower than 16 V

105 sec. after engine start

No relevant DTC present

Threshold Value

Intake air temperature signal voltage higher than 4.93V (266℉/130℃)

Diagnostic Time

Continuous

Mil On Condition

2 Driving Cycle