DTC Description

The control unit of the linear oxygen sensor built inside the PCM monitors short circuit error on all front Heated Oxygen Sensor (HO2S) control lines (VRC, VIP, VG, VN) and PCM sets P0131 with short circuit to ground.

If same code is set again in the next driving cycle, MIL is illuminated.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Electrical Monitoring

1.

Poor Connector Connection

2.

Short to ground in Upstream O2 Sensor Signal Circuit

3.

Defected Upstream O2 Sensor

Enable Conditions

Engine speed higher than 32 RPM

Battery voltage higher than 11 V and lower than 16 V

No relevant DTC present

Threshold Value

Error bit information from HW circuit

Diagnostic Time

Continuous

Mil On Condition

2 Driving Cycle