DTC Description

PCM sets DTC P0137 if the HO2S(B1S2) voltage remains excessively low for a pre-determined time.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Electrical Monitoring

1.

Poor Connector Connection

2.

Short to Ground in Downstream O2 Sensor Signal Circuit

3.

Defected Downstream O2 Sensor

Enable Conditions

•

Lambda closed loop control active

•

Lambda controller not at max. limit

•

Catalyst purge after fuel cut off not active

•

Battery voltage higher than 10 V and lower than 16 V

•

No relevant DTC present

Threshold Value

•

Downstream O2 Sensor Voltage lower than 0.02V and Downstream O2 Sensor Element resistance less than 15 Ω

Diagnostic Time

•

35 sec.

Mil On Condition

•

2 Driving Cycle