DTC Description

If the HO2S signal voltage is fixed at rich status, then feedback control is no longer possible, the PCM sets DTC P2196.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Characteristic Monitoring

1.

Poor Connector Connection

2.

Defected Upstream O2 Sensor

Enable

Condition

Case 1

Sensor Pump current valid

Downstream O2 Sensor operative readiness detected(Downstream O2 sensor voltage lower than 0.25V or higher than 0.56V & Downstream O2 sensor max heating finished)

Active Test not activated

Catalyst purge after fuel cut off not active

Engine speed higher than 600 RPM

Mass air flow less than 83 g/sec.

Exhaust gas Temp. higher than 572℉(300℃) and lower than 1472℉(800℃)

Stable driving condition

Case 2

No Fuel Cut Off

No Full Load

No catalyst overheating protection

Battery voltage higher than 11V and lower than 16V

Threshold

Value

Case 1

Upstream Lambda(rich) below 0.9 and Downstream O2 signal voltage below 0.2V(lean) and lambda controller in limit(-30%)

Case 2

Lambda value below 1.05 when lambda setpoint is 1.15

Diagnostic

Time

Case 1

5 to 100 sec. depending on intake air mass

Case 2

10 sec. after lambda setpoint shift to corresponding side

MIL ON Condition

2 Driving Cycle

Яндекс.Метрика