DTC Description

The PCM monitors front O2 sensor reference voltage circuit(VN) and sets DTC P2243 if front O2 sensor signal stuck is detected.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Electrical Monitoring

1.

Poor Connector Connection

2.

Open in Upstream O2 Sensor Control Circuit

3.

Defected Upstream O2 Sensor

Enable Conditions

Sensor Pump Current Valid

Battery voltage higher than 11V and lower than 16V

Threshold Value

P0135 detection and upstream O2 sensor voltage less than 0.2V for 5 sec during internal test

Diagnostic Time

15 sec.

MIL ON Condition

2 Driving Cycle