Many malfunctions in the electrical system are caused by poor connection. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration,or damage.
Has a problem been found?
![]() | ▶ Repair as necessary and go to "Verification of Vehicle Repair" procedure. |
![]() | ▶ Perform following procedures. |
Ignition "OFF"
Disconnect Auto defogger humidity Potentiometer(actuator) and A/C control module main harness connector.
Measure resistance between OPEN terminal of Auto defogger humidity Potentiometer(actuator) harness connector and OPEN terminal of A/C-ECU harness connector.
Measure resistance between CLOSE terminal of Auto defogger humidity Potentiometer(actuator) harness connector and CLOSE terminal of A/C control module harness connector.
Specification : Below 1Ω
Is measured value within specification?
![]() | ▶ Perform following procedures. |
![]() | ▶ Check for open in harness. ▶ Repair as necessary and then go to "Verification of Vehicle Repair" procedure. |
Ignition "OFF"
Disconnect Auto defogger humidity Potentiometer(actuator) and A/C control module main harness connector.
Measure resistance between OPEN terminal of Auto defogger humidity Potentiometer(actuator) harness connector and chassis ground .
Measure resistance between CLOSE terminal of Auto defogger humidity Potentiometer(actuator) harness connector and chassis ground.
Specification : Infinity
Is measured value within specification?
![]() | ▶ Go to " Component inspection" procedure . |
![]() | ▶ Check for short to ground in control harness. ▶ Repair as necessary and then go to "Verification of Vehicle Repair" procedure. |