Component Inspection
1.

Connect GDS to Data Link Connector(DLC).

2.

Ignition "ON".

3.

Perform "Actuator Control - Apply" and "Actuator Control - Release" in "Actuation Test" with GDS.

4.

Is the parameter displayed within specification ?

▶ Fault might be intermittent and caused either by poor contact in connectors or wiring harness, or it has been repaired and control module memory is not cleared yet. Thoroughly check terminal of battery, all connectors (and connections) for looseness, bending, corrosion, contamination, deterioration, and/or damage.

▶ Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.

▶ Substitute with known-good LH EPB actuator and then check for proper operation. If problem is corrected, replace LH EPB actuator and then go to "Verification of Vehicle Repair" procedure.