DTC Description

The TPMS Module monitors the RF signal of the FR TPMS sensor and if its temperature is more than 239℉(115℃), this DTC is set.

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

Monitoring the RF signals of the sensor

1.

Damaged tire

2.

Surrounding high temperature

3.

Driving with low pressure tire

4.

Excessive braking at driving

Enable Conditions

IG KEY ON

Threshold value

When the final temperature values received of ECU is more than 239℉ (115℃) and sensor data missing for 180s while driving

TPMS Lamp

Lamp Off