Inspection
Ignition Lock Switch Inspection
1.

Disconnect 2P-connector from a ignition lock switch.

2.

Disconnect the ignition lock switch. (if you can install a tester with the switch fixed, this step can be omission)

3.

Check for continuity between terminals. (refer to the table below)

note

If there is difference between what tested and the table above, replace the ignition lock switch with a new one.

Pedal position

Clutch switch

Ignition lock

switch

Released 

Pressed

(Continuity)

Released (Open)

Fully pressed 

Released (Open)

Pressed

(Continuity)

Standard value

Full stroke (A): 12.0 ± 0.3mm (0.4724 ± 0.0118 in.)

ON-OFF point (B): 2.0 ± 0.3mm (0.0787 ± 0.0118 in)

4.

If there is difference between what tested and the table above, replace the ignition lock switch with a new one.