Inspection
1.

Disconnect the negative (-) battery terminal.

2.

Remove the glove box housing.

(Refer to BD group - "Crash pad")

3.

Remove the PDM relay box (A) after loosening the screws (2EA) and desconnecting the connector.

IG2 Relay

Check for continuity between the terminals.

1.

There should be continuity between the No.1 in the B and No.2 in the B terminals when power and ground are connected to the No.3 in the A and No.4 terminals in the B terminals.

2.

There should be no continuity between the No.1 in the B and No.2 terminals in the B terminals when power is disconnected.

IG1 Relay

Check for continuity between the terminals.

1.

There should be continuity between the No.7 in the A and No.8 in the A terminals when power and ground are connected to the No.3 in the A and No.10 terminals in the A terminals.

2.

There should be no continuity between the No.7 in the A and No.8 terminals in the A terminals when power is disconnected.

ACC Relays

Check for continuity between the terminals.

1.

There should be continuity between the No.7 in the A and No.6 in the A terminals when power and ground are connected to the No.1 in the A and No.3 terminals in the A terminals.

2.

There should be no continuity between the No.7 in the A and No.6 terminals in the A terminals when power is disconnected.

Яндекс.Метрика