Ignition "OFF".
Disconnect evaporator temperature sensor.
Using the multi-tester, Measure resistance between terminal "1" and "2" of evaporator temperature sensor.
Evaporator core temperature [°C (℉)] | Resistance[KΩ] | Voltage[V] |
-10 (14) | 17.93 | 3.22 ± 0.5 |
-5 (23) | 14.22 | 2.94 ± 0.5 |
0 (32) | 11.36 | 2.67 ± 0.5 |
5 (41) | 9.14 | 2.39 ± 0.5 |
10 (50) | 7.40 | 2.13 ± 0.5 |
15 (59) | 6.02 | 1.88 ± 0.5 |
20 (68) | 4.94 | 1.66 ± 0.5 |
25 (77) | 4.066 | 1.45 ± 0.5 |
30 (86) | 3.369 | 1.26 ± 0.5 |
35 (95) | 2.85 | 1.1 ± 0.5 |
40 (104) | 2.348 | 0.95 ± 0.5 |
45 (113) | 1.975 | 0.83 ± 0.5 |
50 (122) | 1.668 | 0.72 ± 0.5 |
Remove the crash pad.(Refer to BD group - Crash pad).
Remove the cowl cross bar.(Refer to BD group - Crash pad).
Disconnect evaporator sensor connector.
Remove the heater unit cover(A).
Remove the evaporator sensor(A).
Installation is the reverse order of removal.