Component Location
General Description

The Evaporator sensor is a negative temperature coefficient thermistor that is mounted at the evaporator core. The A/C ECU uses the evaporator sensor data to control A/C compressor operation in order to prevent evaporator freezing.

DTC Description

Air conditioner Control Module sets DTC B1241 if Evaporator sensor has been detected below 0.1V for 0.3 seconds.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage check

•

Short circuit in harness

•

Faulty Evaporator sensor

•

Faulty A/C Control Unit

Enable Conditions

•

IG KEY ON

Threshold value

•

Evaporator sensor has been detected below 01.V for 0.3 seconds.

Failsafe

•

Control with the value of -2℃(28.4℉)

Specification
※ Resistance value of evaporator sensor as a function of temperature.

Temperature(℃/℉)

Resistance(㏀)

Temperature(℃/℉)

Resistance(㏀)

-10/-14

18

20/68

4.8

0/32

11

30/86

3.3

10/50

7.3

40/104

2.3

Diagnostic Circuit Diagram