Component Location
General Description

Alternator output and power demand of all electrical loads and systems must be matched to each other as ideally as possible so that the entire system is reliable and trouble-free in operation. The ECM monitors alternator output deviation from the signal of the FR terminal of the alternator when the engine is running.

DTC Description

P0625 is set when alternator control circuit is short to ground at IG "ON"

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

•

Signal Monitoring

•

Short to Ground in harness

•

Poor connection or damaged harness

Enable Conditions

•

IG "ON"

Threshold value

•

Signal is low

Diagnosis Time

•

-

MIL On Condition

•

OFF

Diagnostic Circuit Diagram