DTC Description

P2002 is set when 1) Differncial pressure below lower limit value at exhaust flow above specified value(Case 1) or 2) Differential pressure above maximum acceptable value(Case 2) or 3) too slight change of differential pressure compared to exhaust flow(Case 3) is detected.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage Monitoring

1.

Differncial pressure sensor wiring

2.

Differncial pressure sensor component

3.

Differncial pressure sensor hose line

Misinstallation/Clogging/Freezing/Crack

4.

Failed CPF

5.

Too much soot loading inside CPF

Enable Conditions

IG KEY "ON"

Threshold value

Refer to DTC description

Diagnosis Time

(Case 1) - 15 sec.

(Case 2) - 25 sec.

(Case 3) - 2 sec.

Fail Safe

Fuel cut

NO

Case 1,3

Soot simulation ON mode activated

Reduced regeneration mileage

Case 2

Torque reduction

EGR Off

NO

Fuel Limit

NO

Check Lamp

BLINK

Яндекс.Метрика