EGR actuatior resistance | EGR actuator frequency | EGR acturator duty | |
Motor | 23 Ω (terminal 1-3) | 1000 Hz | 0 ~ 100 % |
Position sensor | 6.11 kΩ (terminal 5-6) | - | - |
6.03 kΩ (terminal 4-5) | - | - | |
170.1 Ω (terminal 4-6) | - | - |
Fig 1) EGR actuator motor(-) is controlled at idle or deceleration
Fig 2) EGR actuator motor(+) is controlled at acceleration