Monitor GDS Data
1.

Connect GDS to data link connector. (DLC)

2.

Engine "ON".

3.

Monitor the "Main function activation status, HLL position, DBL position" parameter on the GDS.

4.

Check the operation of "HLL position-RH" use Actuation test.

Fig.1) ENG "ON" - Actuation Test - HLL Low Position

Fig.2) ENG "ON" - Actuation Test - HLL High Position

5.

Is parameter displayed within specifications ?

▶ Fault is intermittent caused by poor contact in the sensor’s and/or AFLS ECU’s connector or was repaired and AFLS ECU memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and go to "Verification of vehicle Repair" procedure.

▶ Go to " Inspection/Repair " procedure.