DTC Description

This is DTC which is related with communication error between IPM and other units.

※ Control Units : IPM(Intelligent integrated Platform Module), SMK(Smart Key Module)

Case1: After short between CAN Low Line and High Line, short to ground together.

Case2: After short between CAN Low Line and High Line, short to power together.

※ This code is occurred when It is not possible to transmit data by CAN Line in those way of Software and Hardware. But, It is possible to receive data by CAN Line.

This code reports BUS OFF status when data transmit error count number is over 255.

The purpose is to verify the status of CAN controller and CAN communication line when error is detected.

According to operation condition, some of module which are connected to CAN line may not detect B1603.

Also, B1602 coincides with B1603 at all times.

DTC Detectiong Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

CAN Communication Check

IPM are not Sleep condition

1.

CAN High and Low Line short to ground coincident

2.

CAN High and Low Line short to battery coincident

Enable Conditions

IPM power on

Threshold Value

CAN high : 0V or B+

CAN low : 0V or B+

Diagnostic Time

Immediately

DTC Erasing Time

DTC is erased immediately after trouble fixed

Яндекс.Метрика