DTC Description

PCM monitors output signals from TPS1 every 8.5 seconds. If an output signal is below 0.25V for more than 0.1 seconds, the PCM sets a P0122 DTC.

DTC Detecting Condition

Item

Detecting Condition

Possible cause

DTC Strategy

Signal low

1.

Poor Connection

2.

Open or short to ground in power harness

3.

Short to ground in signal harness

4.

TPS

5.

PCM

Enable Conditions

IG "ON"

Threshold value

The voltage of TPS less than 0.25V

Diagnosis Time

Continuous (more than 0.1 sec. failure for every 8.5 sec.test)

MIL On Condition

1 Driving Cycle

Яндекс.Метрика