DTC Description

P0253 is set when "0"A in control circuit of P-PRV (integrated with high pressure pump) is detected for more than specified duration. This code is due to open or short to ground in P-PRV control circuit or P-PRV internal open.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage monitoring

1.

P-PRV circuit problem

2.

P-PRV

Enable Conditions

IG key ON

Case 1

Threshold Value

Short to ground in P-PRV control circuit.

Diagnostic Time

0.28 sec.

Case 2

Threshold Value

Open in P-PRV control circuit.

Diagnostic Time

0.22 sec.

Fail Safe

Fuel cut

NO

-

EGR Off

NO

Fuel Limit

YES

Check Lamp

ON