DTC Description

P0108 is set when the voltage above 4.85V - maximum output voltage of Barometric pressure sensor - is detected for more than 0.8 sec. This code is due to fee failure of the sensor inside of ECM.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage monitoring

1.

Atmospheric pressure sensor (ECM component)

Enable Conditions

•

Engine running

Threshold Value

•

When output voltage is above the maximum value (above 4.85V).

Diagnostic Time

•

0.8 sec.

Fail Safe

Fuel cut

NO

•

Regarding pressure as 1000hpa when failure

EGR Off

YES

Fuel Limit

YES

MIL

ON