DTC Description

P0117 is set when the voltage below 225mV - minimum output voltage of ECTS - is detected for more than 2.0 sec. This code is due to short to ground in signal circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

Voltage Monitoring

1.

ECTS circuit

2.

ECTS

Enable Conditions

IG key ON

Threshold value

Output signal is lower than minimum value (225mV).

Diagnosis Time

2 sec.

Fail Safe

Fuel cut

NO

Engine Hot condition

: Fixed at 80℃

Engine cold/cranking

: Fixed at -10℃

EGR Off

NO

Fuel Limit

NO

MIL

OFF