DTC Description

P0117 is set when the voltage below 225mV - minimum output voltage of ECTS - is detected for more than 2.0 sec. This code is due to short to ground in signal circuit.

DTC Detecting Condition

Item

Detecting Condition

Possible Cause

DTC Strategy

•

Voltage Monitoring

1.

ECTS circuit

2.

ECTS

Enable Conditions

•

IG key ON

Threshold value

•

Output signal is lower than minimum value (225mV).

Diagnosis Time

•

2 sec.

Fail Safe

Fuel cut

NO

•

Engine Hot condition

: Fixed at 80℃

•

Engine cold/cranking

: Fixed at -10℃

EGR Off

NO

Fuel Limit

NO

MIL

OFF