P2112 is set when ACV is open more than 6% of target value over 1sec or stuck close over 3sec.
Item | Detecting Condition | Possible Cause | ||
DTC Strategy |
•
Signal monitoring | 1. ACV | ||
Enable Conditions |
•
Engine running | |||
Threshold Value |
•
ACV is open more than 6% of target value over 1sec or stuck close over 3sec. | |||
Diagnostic Time |
•
Refer to threshold value | |||
Fail Safe | Fuel cut | NO |
•
- | |
EGR Off | YES | |||
Fuel Limit | YES | |||
Check Lamp | ON |